Thursday, June 30, 2011

Design a Temperature Indicator


Abstract- This circuit is a temperature indicator circuit or differential instrumentation amplifier using a transducer bridge. This circuit is calibrate in degrees Celsius or Fahrenheit. In the circuit used buffer in  and  points for exact voltage of  and  points. Because gain is always 1 of buffer circuit. Then the output voltage of buffers is input voltage of differential amplifier. The differential amplifier is difference voltage of  and  points using 741 Op-Amp. When temperature is increased then resistance  is also decreased and output voltage  is decreases and when temperature is decreased then resistance  is also increased and output voltage  is increases.

I.      Introduction
The temperature indicator is a circuit that indicates of temperature in degrees Celsius or Fahrenheit. The temperature is inversely proportional to the resistance or transducer.

II.   Description
The Fig.01 simplified a temperature indicator circuit using a transducer bridge. A restive transducer whose resistance changes as a function of some physical energy or temperature is connected in one arm of the bridge with a small circle around it and is denoted by , where  is the resistance of the transducer and  is the change in resistance .

opamp.JPG
Fig.01 - Temperature indicator

The resistors,and  are selected so that they are equal in value to the transducer resistance  at some reference condition.
or
The temperature to be measured changes, the resistance of the transducer also changes, which cause the bridge to unbalance. The output voltage of the bridge can be expressed as a function of the change in resistance of the transducer.

Let the change in resistance of RT be. Since RB and RC are fixed resistors, the voltage  is constant and the voltage  varies as a function of the change in resistance RT.
So,
If , then
Generally, the change in resistance of RT increase  is very small.
So, the approximately.
The gain of the basic differential amplifier is .
So, the output voltage is

The following data table of the circuit,
(𝜴)
(V)
(V)
(V)
(V)
  (V)
100
4.545
2.5
4.545
2.5
-2.045
1 K
2.5
2.5
2.5
2.5
39.64 μ
10 K
.833
2.5
.833
2.5
1.67

We get from the simulation circuit and data table, when temperature is increased then resistance  is also decreased and output voltage  is decreases. When temperature is decreased then resistance  is also increased and output voltage  is increases.




III.     Conclusion
In the circuit used as the transducer in the bridge circuit is a thermistor and replaced output voltmeter to temperature indicating meter. Then temperature indicating meter is calibrate in degrees Celsius or Fahrenheit. The bridge can be balanced at a desired reference condition, for instance 250C. As the temperature varies from its reference value, the resistance of the thermistor changes and the bridge become unbalanced. This unbalance bridge in turn produces the meter movement.

Wednesday, June 22, 2011

Water Level Indicator

Theory or What is it:
            For the residents who live in high buildings, low water pressure is a very common problem, especially when many people use the water at the same time. Therefore, many people install a water tower on the roof of the building. The water is stored at a water tank at the basement first. Then it is pumped into the water tower on the roof using a pumping motor. In this manner, the low water pressure problem can be improved and the water can be used in a more efficient way.

            The water level indicator is a device that indicates with signal of the level of water of the tank. This level is proportional to feedback of input device. This device is use as deeply water tank, large container and etc.

Required instrument:
1.      Op_Amp (741) × 4
2.      LED  × 4
3.      Resistance (2 kΩ × 5) & (220 Ω ×4)
4.      DC source (10v×1) &(12v×2)
5.      Ground

Circuit diagram:



Procedure:
1.      Firstly the circuit was designed on electronic workbench.
2.      Then the value of R is the voltage of V divided by numbers of resistance R.
3.      The output of all Op-amp by LED.
4.      If Vin is zero then no light will ON and if we gradually increase Vin then the numbers of LED ON will increase. Because all Op_Amp will reach to +Vsat one by one and proportional to water level.    

Simulation result:
            We regarded from the simulation that, the Vin is decrease or level of water is low level then the BLUE LED is ON. If Vin is increase or level of water is medium level then the GREEN LED is ON. And if Vin is more increase or level of water is brimming then the RED LED is ON.

Conclusion:
            In the circuit Vin is increase or level of water is medium level then the GREEN LED & BLUE LED is ON but there only GREEN LED will be ON. And if Vin is more increase or level of water is brimming then the all LED is ON but there only RED LED will be ON. This is the problem of designed circuit.