Abstract- This circuit is a temperature indicator circuit or differential instrumentation amplifier using a transducer bridge. This circuit is calibrate in degrees Celsius or Fahrenheit. In the circuit used buffer in
and
points for exact voltage of
and
points. Because gain is always 1 of buffer circuit. Then the output voltage of buffers is input voltage of differential amplifier. The differential amplifier is difference voltage of
and
points using 741 Op-Amp. When temperature is increased then resistance
is also decreased and output voltage
is decreases and when temperature is decreased then resistance
is also increased and output voltage
is increases.
I. Introduction
The temperature indicator is a circuit that indicates of temperature in degrees Celsius or Fahrenheit. The temperature is inversely proportional to the resistance or transducer.
II. Description
The Fig.01 simplified a temperature indicator circuit using a transducer bridge. A restive transducer whose resistance changes as a function of some physical energy or temperature is connected in one arm of the bridge with a small circle around it and is denoted by
, where
is the resistance of the transducer and
is the change in resistance
.

Fig.01 - Temperature indicator
The resistors
,
and
are selected so that they are equal in value to the transducer resistance
at some reference condition.
or
The temperature to be measured changes, the resistance of the transducer also changes, which cause the bridge to unbalance
. The output voltage of the bridge can be expressed as a function of the change in resistance of the transducer.
Let the change in resistance of RT be
. Since RB and RC are fixed resistors, the voltage
is constant and the voltage
varies as a function of the change in resistance RT.
So, 
If
, then
Generally, the change in resistance of RT increase
is very small.
So, the approximately
.
The gain of the basic differential amplifier is
.
So, the output voltage is
The following data table of the circuit,
| | | | | | |
| 100 | 4.545 | 2.5 | 4.545 | 2.5 | -2.045 |
| 1 K | 2.5 | 2.5 | 2.5 | 2.5 | 39.64 μ |
| 10 K | .833 | 2.5 | .833 | 2.5 | 1.67 |
We get from the simulation circuit and data table, when temperature is increased then resistance
is also decreased and output voltage
is decreases. When temperature is decreased then resistance
is also increased and output voltage
is increases.
III. Conclusion
In the circuit used as the transducer in the bridge circuit is a thermistor and replaced output voltmeter to temperature indicating meter. Then temperature indicating meter is calibrate in degrees Celsius or Fahrenheit. The bridge can be balanced at a desired reference condition, for instance 250C. As the temperature varies from its reference value, the resistance of the thermistor changes and the bridge become unbalanced. This unbalance bridge in turn produces the meter movement.

Affordable and easy temperature indicates the heat indicator of a heat drain in high power tour can be designed using this electronic circuit diagram.