Thursday, June 30, 2011

Design a Temperature Indicator


Abstract- This circuit is a temperature indicator circuit or differential instrumentation amplifier using a transducer bridge. This circuit is calibrate in degrees Celsius or Fahrenheit. In the circuit used buffer in  and  points for exact voltage of  and  points. Because gain is always 1 of buffer circuit. Then the output voltage of buffers is input voltage of differential amplifier. The differential amplifier is difference voltage of  and  points using 741 Op-Amp. When temperature is increased then resistance  is also decreased and output voltage  is decreases and when temperature is decreased then resistance  is also increased and output voltage  is increases.

I.      Introduction
The temperature indicator is a circuit that indicates of temperature in degrees Celsius or Fahrenheit. The temperature is inversely proportional to the resistance or transducer.

II.   Description
The Fig.01 simplified a temperature indicator circuit using a transducer bridge. A restive transducer whose resistance changes as a function of some physical energy or temperature is connected in one arm of the bridge with a small circle around it and is denoted by , where  is the resistance of the transducer and  is the change in resistance .

opamp.JPG
Fig.01 - Temperature indicator

The resistors,and  are selected so that they are equal in value to the transducer resistance  at some reference condition.
or
The temperature to be measured changes, the resistance of the transducer also changes, which cause the bridge to unbalance. The output voltage of the bridge can be expressed as a function of the change in resistance of the transducer.

Let the change in resistance of RT be. Since RB and RC are fixed resistors, the voltage  is constant and the voltage  varies as a function of the change in resistance RT.
So,
If , then
Generally, the change in resistance of RT increase  is very small.
So, the approximately.
The gain of the basic differential amplifier is .
So, the output voltage is

The following data table of the circuit,
(𝜴)
(V)
(V)
(V)
(V)
  (V)
100
4.545
2.5
4.545
2.5
-2.045
1 K
2.5
2.5
2.5
2.5
39.64 μ
10 K
.833
2.5
.833
2.5
1.67

We get from the simulation circuit and data table, when temperature is increased then resistance  is also decreased and output voltage  is decreases. When temperature is decreased then resistance  is also increased and output voltage  is increases.




III.     Conclusion
In the circuit used as the transducer in the bridge circuit is a thermistor and replaced output voltmeter to temperature indicating meter. Then temperature indicating meter is calibrate in degrees Celsius or Fahrenheit. The bridge can be balanced at a desired reference condition, for instance 250C. As the temperature varies from its reference value, the resistance of the thermistor changes and the bridge become unbalanced. This unbalance bridge in turn produces the meter movement.

1 comment:

  1. Affordable and easy temperature indicates the heat indicator of a heat drain in high power tour can be designed using this electronic circuit diagram.